Gaseous hydrogen tank model

Tank position option

The gaseous hydrogen tank model has four possible installation position:

wing_pod : Tank installed under the wing with user specified position.
underbelly : Tank installed under and outside the fuselage.
in_the_cabin : Tank installed at the middle section inside the fuselage.
in_the_back : Tank installed at the rear section inside the fuselage.

Multiple tank option

This option is activated by changing the “number_of_tank” variable in the input file. Please note it will only be used for in-fuselage installation, as indicated in the assumptions.

n

Tank outer diameter compared to single tank case

1

1

2

\(\frac{1}{2}\)

3

\(\frac{1}{1 + \frac{2}{3}\sqrt{3}}\)

4

\(\frac{1}{1 + \sqrt{2}}\)

5

\(\frac{1}{1 + \sqrt{2(1+1/\sqrt{5})}}\)

6

\(\frac{1}{3}\)

7

\(\frac{1}{3}\)

8

\(\frac{1}{1 + \csc(\pi/7)}\)

9

\(\frac{1}{1 + \sqrt{2(2+\sqrt{2})}}\)

This table indicates the maximum diameter of tanks located inside the fuselage as given by [Kra67].